2 resultados para 110504 Oral and Maxillofacial Surgery

em Universidade Complutense de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation goes into the new field from applied linguistics called forensic linguistics, which studies the language as an evidence for criminal cases. There are many subfields within forensic linguistics, however, this study belongs to authorship attribution analysis, where the authorship of a text is attributed to an author through an exhaustive linguistic analysis. Within this field, this study analyzes the morphosyntactic and discursive-pragmatic variables that remain constant in the intra-variation or personal style of a speaker in the oral and written discourse, and at the same time have a high difference rate in the interspeaker variation, or from one speaker to another. The theoretical base of this study is the term used by professor Maria Teresa Turell called “idiolectal style”. This term establishes that the idiosyncratic choices that the speaker makes from the language build a style for each speaker that is constant in the intravariation of the speaker’s discourse. This study comes as a consequence of the problem appeared in authorship attribution analysis, where the absence of some known texts impedes the analysis for the attribution of the authorship of an uknown text. Thus, through a methodology based on qualitative analysis, where the variables are studied exhaustively, and on quantitative analysis, where the findings from qualitative analysis are statistically studied, some conclusions on the evidence of such variables in both oral and written discourses will be drawn. The results of this analysis will lead to further implications on deeper analyses where larger amount of data can be used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (). However, no significant differences were found () for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery () but no statistical differences were found in SCT (). Correlations between pre- and postsurgery were found for all tonometers used, with and for the air pulse tonometer, and for Perkins, and and for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.